Stop the Fire. Save the Hardware.

Advanced Fire Suppression systems for Ireland's critical infrastructure. We protect your servers, data, and business continuity without the collateral damage of water.

 
The "Water vs. Gas" Reality

Sprinklers Save Buildings. We Save Businesses. Standard fire protection uses water, which destroys electronics as fast as fire does.

Zero Residue: Our clean agent gases (like Novec 1230 / FK-5-1-12) extinguish fires in seconds and evaporate immediately, leaving no residue to clean up.
Business Continuity: Your servers stay running. There is no power-down required for discharge in many scenarios, and no water damage to restore.
Rapid Reaction: Suppression systems detect and act at the incipient stage of a fire, long before a standard smoke detector would trigger a building evacuation.


For Data & Electrical (Clean Agents)

Server Rooms | Comms Rooms | Switchgear

Inert Gas (IG-55/IG-541): Environmentally neutral gases that lower oxygen levels to suppress fire without suffocating humans. Ideal for large data halls.
Synthetic Agents (Novec 1230): Chemical cooling agents that extinguish fire instantly. Perfect for smaller server rooms with limited cylinder storage space.
CO2 Systems: For unoccupied electrical substations and industrial machinery.


For Kitchens (Wet Chemical)

Restaurants | Hotels | Universities | Canteens | Hospitality

Class F Protection: Water spreads a grease fire; our Wet Chemical systems saponify the burning fat, creating a cooling blanket that seals the fire.
Appliance Specific: Nozzles targeted directly at fryers, griddles, and extraction canopies.
Automatic Cut-Off: Automatically shuts down the gas supply to the kitchen upon activation.

A Leaky Room is a Dangerous Room. Gas suppression relies on the room holding the gas for 10 minutes (Hold Time) to ensure the fire stays out.

Door Fan Testing: We perform mandatory Room Integrity Testing (RIT) annually to strictly comply with ISO 14520 and Irish regulations.
Leak Sealing: If your room fails, our construction team can identify leakage points (cable penetrations, door seals) and seal them to ensure a pass.

Fully F-Gas Compliant. Handling fire suppression gases requires strict adherence to European F-Gas regulations.

Certified Engineers: Every technician handling your cylinders holds a valid F-Gas license.
Green Solutions: We prioritize agents with a Global Warming Potential (GWP) of 1 or less, future-proofing your system against environmental bans.

Critical Systems Need Critical Care.

Semi-Annual Servicing: Suppression systems must be serviced twice a year (every 6 months) to remain compliant.
Cylinder Level Checks: We use ultrasonic liquid level detection to verify cylinder contents without disconnecting them.
10-Year Hydrostatic Testing: We manage the lifecycle of your cylinders, handling the mandatory 10-year pressure testing and refilling off-site.

Fire suppression systems Ireland

If your system has leaks, your expensive suppression system is useless.

Need more Advice?